  • Autoranging; display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
  • Display update rate: 2/sec, nominal
  • Operating temperature: 0 °C to 45 °C at < 70 % R.H
  • True-rms digital multimeter with temperature and backlight
  • Overrange indication
  • Auto power off to save battery life
  • Min/max, data hold and range lock
  • Separate door for easy battery and fuse access
  • Magne-Grip™ Holster with magnetic hanging strap
Qty:
Compare

The Amprobe 34XR-A Digital Multimeter, a True-rms digital multimeter with temperature and backlight for contractors and field service technicians.

Features:

  • Autoranging; display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
  • Display update rate: 2/sec, nominal
  • Operating temperature: 0 °C to 45 °C at < 70 % R.H
  • True-rms digital multimeter with temperature and backlight
  • Overrange indication
  • Auto power off to save battery life
  • Min/max, data hold and range lock
  • Separate door for easy battery and fuse access
  • Magne-Grip™ Holster with magnetic hanging strap
FEATURE34XR-A
DC Voltage400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
AC Voltage400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
DC Current400.0 µA, 4.000 mA, 40.00 mA, 300.0 mA, 10 A
AC Current400.0 µA, 4.000 mA, 40.00 mA, 300.0 mA, 10 A
Resistance400.0 O, 4.000 kO, 40.00 kO, 400.0 kO, 4.000 MO. 40.00 MO
Continuity
Diode
VolTect™ Non-Contact Voltage Detection
Capacitance4.000 µF, 40.00 µF, 400.0 µF, 4000 µF
Frequency4.000 kHz, 40.00 kHz, 400.0 kHz, 1 MHz
Temperature1832 °F (1000 °C)
Duty cycle0.0 % → 90.0 %
Logic test
Inductance
dBm

 

Specifications
DC Voltage ranges400 mV, 4 V, 40 V, 400 V, 1000 V
DC Voltage accuracyAll ranges: ± (0.5 % rdg + 1 dgt)
DC Voltage resolution100 µV
AC Voltage (45 Hz to 2 kHz) True-rms ranges400 mV, 4 V, 40 V, 400 V, 750 V
AC Voltage (45 Hz to 2 kHz) True-rms accuracy400 mV range, 45 to 100 Hz: ± (1.2 % rdg + 8 dgts)

750 V range: 45 to 1 kHz: ± (2.0 % rdg + 8 dgts)

All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 8 dgts)

All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 8 dgts)

AC Voltage (45 Hz to 2 kHz) True-rms resolution100 µV
DC Current ranges400 µA, 4 mA, 40 mA, 300 mA, 10 A
DC Current accuracy400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt)

10 A range: ± (2.0 % rdg + 3 dgts)

DC Current resolution0.1 µA
AC Current (45 Hz to 1 kHz) True-rms ranges400 µA, 4 mA, 40 mA, 300 mA, 10 A
AC Current (45 Hz to 1 kHz) True-rms accuracy400 µA to 300 mA ranges: ± (1.5 % rdg + 8 dgts)

10 A range: ± (2.5 % rdg + 10 dgts)

AC Current (45 Hz to 1 kHz) True-rms resolution0.1 µA
Resistance ranges400 mO 4 kmO 40 kmO 400 kmO 4 MmO 40 MmO
Resistance accuracy400, 4 k, 40 k, 400 k, 4 MmO ranges: ± (1.0 % rdg + 4 dgts)

40 MmO range: ± (2.0 % rdg + 5 dgts)

Resistance resolution100 mmO
Continuity audible indication< 35 mO
Weight1 kg

Amprobe