No Preview Available
Product images will be displayed here once uploaded
Testo 350 Analysis Box for Exhaust Gas Analysis Systems
SKU:
Brand: Testo
Category: Test & Measuring Equipment › Emission Analyzer › Flue Gas Analyzer
Ideal for professional flue gas analysis and industrial emissions measurement on industrial engines, burners, gas turbines and in thermal processes: the testo 350 flue gas analyzer performs a varie...
Contact us for pricing
This product requires a custom quote
Quantity
Description
Ideal for professional flue gas analysis and industrial emissions measurement on industrial engines, burners, gas turbines and in thermal processes: the testo 350 flue gas analyzer performs a variety of measuring and analysis tasks, impresses over the long term thanks to its heavy-duty industrial design and is also suitable for complex data acquisition.
The testo 350 flue gas analyzer comprises two units
- The testo 350 Control Unit (separate product) with a clear graphic display, allows you to control emissions measurement. Operation is really easy: burner, gas turbine, engine and user-defined applications are available for selection in the menu. The Control Unit enables remote control of the analyzer unit even when there is a spatial separation of the flue gas pipe and the setting location – particularly recommended for emissions measurements on large plants.
- The testo 350 analyzer unit is just what you need for carrying out emissions measurement, because it contains all the sensor technology and electronics. The testo 350 analyzer unit includes an O2 gas sensor as standard, but at least one additional sensor must be connected for commissioning (can be used with a maximum of 6 sensors). When connecting the optional sensors, you can choose between gas sensors for CO, CO2, NO, NO2, SO2, H2S or CxHy.
The measuring range extension enables unrestricted measurements to be carried out, even when there are high gas concentrations. In order to protect the sensor technology, the measuring range extension (dilution) is automatically activated when there are unexpectedly high gas concentrations. The measuring range of a selected sensor can be extended by a specific factor. The service opening on the underside of the instrument allows fast access to all relevant serviceable and wearing parts, such as pumps and filters, enabling users to clean or replace these. In addition, the testo 350 has numerous instrument diagnosis functions. Instrument notifications are output in cleartext, making them easy to understand. The current status of the flue gas analyzer is constantly displayed.
Using the testo 350 analyzer unit
The analyzer unit can be operated with the Control Unit and it can also be used in direct combination with a PC/notebook and the easyEmission software (via USB, Bluetooth® 2.0 or CANCase). After programming, the analyzer unit can carry out measurements and save the results autonomously. It is also possible to display or transmit the measurement data from the analyzer unit to the Control Unit or software.
To send the measurement report straight away, you can also use our free App which turns your Android smartphone or tablet into a display device for the analyzer unit.Additional Details
testo 350 analyzer unit, equipped with O 2 , including differential pressure sensor, temperature probe input type K NiCr-Ni and type S, Pt10Rh-Pt, Testo data bus connection, rechargeable battery, integrated combustion air probe (NTC), trigger input, measurement data memory, USB interface, carrying strap kit and test protocol. Please note: The testo 350 analyzer unit can only be used in combination with the testo 350 Control Unit or the "easyEmission" software. These items are available separately.
Additional Information
No Additional Information
Product dimensions are not available.
Specifications
Measuring range
600 to +1150 hPa
Accuracy
±10 hPa
Resolution
1 hPa
Measuring range
100 to 18000 ppm
Accuracy
< 400 ppm (100 to 4000 ppm) / 4000 ppm)
Resolution
10 ppm
Min. O₂ requirement in flue gas
2 % + (6.5 x mV butane)
Reaction time t₉₀
< 40 s
Response factor
2
footnote_
Lower explosion limit (LEL) must be adhered to. The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Measuring range
-200 to +200 hPa / -40 to +40 hPa
Accuracy
±1.5 % of mv (+3 to +40 hPa) / ±0.5 hPa (-49.9 to +49.9 hPa) / ±1.5 % of mv (-200 to -50 hPa) / ±0.03 hPa (-2.99 to +2.99 hPa) / ±1.5 % of mv (-40 to -3 hPa) / ±1.5 % of mv (+50 to +200 hPa)
Resolution
0.01 hPa (-40 to +40 hPa) / 0.1 hPa (-200 to +200 hPa)
Measuring range
0 to +10000 ppm
Accuracy
±10 ppm (0 to +199 ppm) / ±5 % of mv (+200 to +2000 ppm) / ±10 % of mv (+2001 to +10000 ppm)
Resolution
1 ppm (0 to +10000 ppm)
Reaction time t₉₀
40 s
footnote_
H₂ only as an indicator
Measuring range
0 to +50 Vol.%
Accuracy
±0.5 Vol.% + 1.5 % of mv (>25 to 50 Vol.%) / ±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%)
Resolution
0.01 Vol.% (0 to 25 Vol.%) / 0.1 Vol.% (> 25 Vol.%)
Reaction time t₉₀
10 s
Measuring range
0 to CO₂ max
Accuracy
calculated from O₂ ±0.2 Vol.%
Resolution
0.01 Vol.%
Measuring range
0 to 500 ppm
Accuracy
±5 % of mv (+40 to +500 ppm) / ±2 ppm (0 to +39.9 ppm)
Resolution
0.1 ppm (0 to +500 ppm)
Reaction time t₉₀
40 s
footnote_
H₂ only as an indicator
Measuring range
0 to +120 %
Resolution
0.1 % (0 to +120 %)
Measuring range
0 to +99.9 °Ctd
Resolution
0.1 °Ctd (0 to +99.9 °Ctd)
Measuring range
0 to +300 ppm
Accuracy
±5 % of mv (+40 to +300 ppm) / ±2 ppm (0 to +39.9 ppm)
Resolution
0.1 ppm (0 to +300 ppm)
Reaction time t₉₀
35 s
Measuring range
0 to +99.9 %
Resolution
0.1 % (0 to +99.9 %)
Measuring range
0 to +4000 ppm
Accuracy
±5 % of mv (+100 to +1999 ppm) / ±10 % of mv (+2000 to +4000 ppm) / ±5 ppm (0 to +99 ppm)
Resolution
1 ppm (0 to +4000 ppm)
Reaction time t₉₀
30 s
Measuring range
0 to +500 ppm
Accuracy
±5 % of mv (+100 to +500 ppm) / ±5 ppm (0 to +99.9 ppm)
Resolution
0.1 ppm (0 to +500 ppm)
Reaction time t₉₀
40 s
Measuring range
0 to +300 ppm
Accuracy
±5 % of mv (+40 to +300 ppm) / ±2 ppm (0 to +39.9 ppm)
Resolution
±0.1 ppm (0 to +300 ppm)
Reaction time t₉₀
30 s
Measuring range
0 to +25 Vol.%
Accuracy
±0.8% of fsv (0 to +25 Vol.%)
Resolution
0.01 Vol.% (0 to +25 Vol.%)
Reaction time t₉₀
20 s (t₉₅)
Measuring range
0 to +5000 ppm
Accuracy
±10 % of mv (+2001 to +5000 ppm) / ±5 % of mv (+100 to +2000 ppm) / ±5 ppm (0 to +99 ppm)
Resolution
1 ppm (0 to +5000 ppm)
Reaction time t₉₀
30 s
Measuring range
0 to 200 ppm
Accuracy
±5 (40 to 200 ppm) / ±2 ppm (0 to 39.9 ppm)
Resolution
0.1 ppm
Reaction time t₉₀
30 s
footnote_
In combination with the special SO2low gas sampling probe 0563 1251 or the industrial heated probe kit 0600 7630
Weight
4800 g
Dimensions
330 x 128 x 438 mm
Operating temperature
-5 to +45 °C
Product-/housing material
ABS
Protection class
IP40
Connectable probes
1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure
Product colour
Black
Battery life
5 h
Battery type
lithium batteries
DC electric tension input
11V to 40V
Power supply
AC mains unit 100V to 240V (50 to 60 Hz)
Dewpoint calculation
0 °Ctd; 99 °Ctd
Hose length
16.2 m (corresponds to 5 probe hose extensions)
Max. dust load
20 g/m³ dust in flue gas
Max. humidity load
70 °C dewpoint temperature
Max. neg. press./flue gas
-300 mbar
Max. pos. press./flue gas
50 mbar
Pump flow
1 l/min. with through-flow monitoring
Trigger input
Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA
Maximum memory
250,000 readings
Interface
data bus; Bluetooth®; USB; IR/IRDA interface; Mains connection; trigger input; Differential Pressure; probe input/ probe inputs; DC-voltage input; dilution gas inlet for measurement range extension
Storage temperature
-20 to +50 °C
footnote_
Measuring range
100 to 40000 ppm
Accuracy
< 400 ppm (100 to 4000 ppm) / 4000 ppm)
Resolution
10 ppm
Min. O₂ requirement in flue gas
2 % + (2 x mV methane)
Reaction time t₉₀
< 40 s
Response factor
1
footnote_
Lower explosion limit (LEL) must be adhered to. The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Measuring range
100 to 21000 ppm
Accuracy
< 400 ppm (100 to 4000 ppm) / 4000 ppm)
Resolution
10 ppm
Min. O₂ requirement in flue gas
2 % + (5 x mV propane)
Reaction time t₉₀
< 40 s
Response factor
1.5
footnote_
Lower explosion limit (LEL) must be adhered to. The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Measuring range
-20 to +50 °C
Accuracy
±0.2 °C (-10 to +50 °C)
Resolution
0.1 °C (-20 to +50 °C)
footnote_
Ambient temperature probe
Measuring range
-200 to +1370 °C
Accuracy
±1 °C (-200 to -100.1 °C) / ±1 °C (200.1 to +1370 °C) / ±0.4 °C (-100 to +200 °C)
Resolution
0.1 °C (-200 to +1370 °C)
Measuring range
0 to +1760 °C
Accuracy
±1 °C (0 to +1760 °C)
Resolution
0.1 °C (0 to +1760 °C)
Measuring range
0 to +40 m/s
Resolution
0.1 m/s (0 to +40 m/s)
Ideal for professional flue gas analysis and industrial emissions measurement on industrial engines, burners, gas turbines and in thermal processes: the testo 350 flue gas analyzer performs a variety of measuring and analysis tasks, impresses over the long term thanks to its heavy-duty industrial design and is also suitable for complex data acquisition.
The testo 350 flue gas analyzer comprises two units
- The testo 350 Control Unit (separate product) with a clear graphic display, allows you to control emissions measurement. Operation is really easy: burner, gas turbine, engine and user-defined applications are available for selection in the menu. The Control Unit enables remote control of the analyzer unit even when there is a spatial separation of the flue gas pipe and the setting location – particularly recommended for emissions measurements on large plants.
- The testo 350 analyzer unit is just what you need for carrying out emissions measurement, because it contains all the sensor technology and electronics. The testo 350 analyzer unit includes an O2 gas sensor as standard, but at least one additional sensor must be connected for commissioning (can be used with a maximum of 6 sensors). When connecting the optional sensors, you can choose between gas sensors for CO, CO2, NO, NO2, SO2, H2S or CxHy.
The measuring range extension enables unrestricted measurements to be carried out, even when there are high gas concentrations. In order to protect the sensor technology, the measuring range extension (dilution) is automatically activated when there are unexpectedly high gas concentrations. The measuring range of a selected sensor can be extended by a specific factor. The service opening on the underside of the instrument allows fast access to all relevant serviceable and wearing parts, such as pumps and filters, enabling users to clean or replace these. In addition, the testo 350 has numerous instrument diagnosis functions. Instrument notifications are output in cleartext, making them easy to understand. The current status of the flue gas analyzer is constantly displayed.
Using the testo 350 analyzer unit
The analyzer unit can be operated with the Control Unit and it can also be used in direct combination with a PC/notebook and the easyEmission software (via USB, Bluetooth® 2.0 or CANCase). After programming, the analyzer unit can carry out measurements and save the results autonomously. It is also possible to display or transmit the measurement data from the analyzer unit to the Control Unit or software.
To send the measurement report straight away, you can also use our free App which turns your Android smartphone or tablet into a display device for the analyzer unit.Additional Details
testo 350 analyzer unit, equipped with O 2 , including differential pressure sensor, temperature probe input type K NiCr-Ni and type S, Pt10Rh-Pt, Testo data bus connection, rechargeable battery, integrated combustion air probe (NTC), trigger input, measurement data memory, USB interface, carrying strap kit and test protocol. Please note: The testo 350 analyzer unit can only be used in combination with the testo 350 Control Unit or the "easyEmission" software. These items are available separately.
