No Preview Available

Product images will be displayed here once uploaded

Testo Globe Thermometer (TC Type K) - for Radiant Heat

SKU:

0602-0743 Testo Globe Thermometer (TC Type K) - for Radiant Heat
Testo logo

Thermal comfort is a crucial factor in terms of a person's physical and mental capabilities – and should be ensured through regular measurements of the individual parameters directly at t...

Contact us for pricing

This product requires a custom quote

In Stock

Quantity

Description

Thermal comfort is a crucial factor in terms of a person's physical and mental capabilities – and should be ensured through regular measurements of the individual parameters directly at the workplace.

In combination with an appropriate measuring instrument, the globe thermometer (thermocouple type K) enables standard-compliant determination and checking of the radiant heat parameter. For example, if a significant temperature difference between the ambient and globe temperature is detected, the cause could be high solar radiation through the window.

The hollow sphere has a diameter of 150 mm and there is a thermocouple type K at its centre for measuring the temperature.

Additional Details

Globe thermometer (Ø 150 mm, TC type K) with 1.45 m fixed cable.


Additional Information
No Additional Information

Product dimensions are not available.


Specifications
General technical data

Weight

385 g

Dimensions

250 x 150 x 150 mm

Cable length

1.4 m

Emissivity

0,95

Probe head diameter

150 mm

Product colour

Black

Temperature - TC Type K (NiCr-Ni)

Measuring range

0 to +120 °C

Accuracy

Class 1 ¹⁾

footnote_

1) According to standard EN 60584-1, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Thermal comfort is a crucial factor in terms of a person's physical and mental capabilities – and should be ensured through regular measurements of the individual parameters directly at the workplace.

In combination with an appropriate measuring instrument, the globe thermometer (thermocouple type K) enables standard-compliant determination and checking of the radiant heat parameter. For example, if a significant temperature difference between the ambient and globe temperature is detected, the cause could be high solar radiation through the window.

The hollow sphere has a diameter of 150 mm and there is a thermocouple type K at its centre for measuring the temperature.

Additional Details

Globe thermometer (Ø 150 mm, TC type K) with 1.45 m fixed cable.