Wika Differential Pressure Gauge with Switch Contacts

Wherever the process pressure has to be indicated locally, and, at the same time, circuits are to be made or broken, the model DPGS43HP.1×0 switchGAUGE can be used.

Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer actual value pointer) moves freely across the entire scale range, independent of the setting.

The set pointer can be adjusted using a removable adjustment key in the window.

Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.

The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels.

As switch contacts magnetic snap-action contacts, reed switches, inductive contacts – for requirements to ATEX – or electronic contacts for triggering a PLC are available.

For further information on the different switch contacts please see data sheet AC 08.01.

Compare

Applications

  • Control and regulation of process values
  • Monitoring of plants and switching of electric circuits
  • For measuring locations with a high differential pressure overload and/or high working pressures (static pressures), also in aggressive ambience
  • Easy-to-read, analogue on-site display needing no external power
  • Pump monitoring and control, filter

Special Features

  • Differential pressure measuring ranges from 0 … 60 mbar
  • High working pressure (static pressure) and high overpressure safety up to 40, 100, 250 or 400 bar
  • Hydraulic cushioning protection against rapid pressure changes
  • Gauges with inductive contacts for use in hazardous areas with ATEX approval
  • Gauges with electronic contact for PLC applications

Description

Wherever the process pressure has to be indicated locally, and, at the same time, circuits are to be made or broken, the model DPGS43HP.1×0 switchGAUGE can be used.

Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer actual value pointer) moves freely across the entire scale range, independent of the setting.

The set pointer can be adjusted using a removable adjustment key in the window.

Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.

The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels.

As switch contacts magnetic snap-action contacts, reed switches, inductive contacts – for requirements to ATEX – or electronic contacts for triggering a PLC are available.

For further information on the different switch contacts please see data sheet AC 08.01.