No Preview Available

Product images will be displayed here once uploaded

FITOK Column End Fittings (Fractional Tube)

SKU:

SS-U-FL4SN7-FL1-LV
FITOK logo

FITOK Column End Fittings — 316/316L stainless steel compression double-ferrule tube fittings (Fractional Tube), FITOK 6D Series. Ordering numbers shown are FITOK's part-number suffix as published ...

Contact us for pricing

This product requires a custom quote

In Stock

Port 1 Size

Quantity

Description

FITOK Column End Fittings — 316/316L stainless steel compression double-ferrule tube fittings (Fractional Tube), FITOK 6D Series. Ordering numbers shown are FITOK's part-number suffix as published in FITOK's 6D dimensional catalog; the material/series prefix (e.g. 'SS-' for 316 stainless) is applied by FITOK at order entry and is not included in the source catalog data.

Available Variants & Specifications

Ordering No. Port 1 Size L (Length) C (Depth) Cx G (Nut Hex) F (Body Hex) E (Min Orifice)
SS-U-FL2SN7-FL1-LV 1/8 1.22(31.0) 0.72(18.3) 0.34(8.6) 0.44(11.1) 0.44(11.1) 0.05(1.3)
SS-U-FL4-NFL1-LV 1/4 1.24(31.5) 0.60(15.2) 0.61(15.5) 0.01(0.3) 0.56(14.3) 0.25(6.4)
SS-U-FL4SN7-FL1-LV 1/4 1.35(34.3) 0.82(20.8) 0.34(8.6) 0.56(14.3) 0.50(12.7) 0.05(1.3)
SS-U-FL6-NFL1-LV 3/8 1.30(33.0) 0.66(16.8) 0.61(15.5) 0.01(0.3) 0.69(17.5) 0.25(6.4)
SS-U-FL6SN7-FL1-LV 3/8 1.44(36.6) 0.91(23.1) 0.34(8.6) 0.69(17.5) 0.63(15.9) 0.05(1.3)
Additional Details

Instrumentation tube fitting for high-pressure, leak-tight, vibration-resistant connections in process, analytical, and instrumentation piping systems. Interchangeable in form, fit and function with other major compression tube fitting brands.


Additional Information

Length

6 cm

Width

4 cm

Height

4 cm

Weight

0.1 kg


Specifications
General

Material

316/316L Stainless Steel (Ni content >= 28.5%)

Connection Style

Compression, double-ferrule tube fitting (FITOK 6D Series)

Standard / Certification

Tested to ASTM F1387; dimensionally interchangeable with other major compression tube fitting brands

Pressure Rating

Rated to the maximum working pressure of the mating FITOK tubing (fitting is not the pressure-limiting component)

Tube Type

Fractional Tube

Column End Tube Size

1/16 in

Technical Specifications

Max working pressure

6000 psig psig

Operating temperature

-28 to +204 °C °C

FITOK Column End Fittings — 316/316L stainless steel compression double-ferrule tube fittings (Fractional Tube), FITOK 6D Series. Ordering numbers shown are FITOK's part-number suffix as published in FITOK's 6D dimensional catalog; the material/series prefix (e.g. 'SS-' for 316 stainless) is applied by FITOK at order entry and is not included in the source catalog data.

Available Variants & Specifications

Ordering No. Port 1 Size L (Length) C (Depth) Cx G (Nut Hex) F (Body Hex) E (Min Orifice)
SS-U-FL2SN7-FL1-LV 1/8 1.22(31.0) 0.72(18.3) 0.34(8.6) 0.44(11.1) 0.44(11.1) 0.05(1.3)
SS-U-FL4-NFL1-LV 1/4 1.24(31.5) 0.60(15.2) 0.61(15.5) 0.01(0.3) 0.56(14.3) 0.25(6.4)
SS-U-FL4SN7-FL1-LV 1/4 1.35(34.3) 0.82(20.8) 0.34(8.6) 0.56(14.3) 0.50(12.7) 0.05(1.3)
SS-U-FL6-NFL1-LV 3/8 1.30(33.0) 0.66(16.8) 0.61(15.5) 0.01(0.3) 0.69(17.5) 0.25(6.4)
SS-U-FL6SN7-FL1-LV 3/8 1.44(36.6) 0.91(23.1) 0.34(8.6) 0.69(17.5) 0.63(15.9) 0.05(1.3)
Additional Details

Instrumentation tube fitting for high-pressure, leak-tight, vibration-resistant connections in process, analytical, and instrumentation piping systems. Interchangeable in form, fit and function with other major compression tube fitting brands.